TB-500 10mg lab test from Nova Labs, June 2026

Uzorak tested TB-500 10mg from Nova Labs on Jun 24, 2026. It measured 99.18% purity and 9.42 mg against 10 mg on the label.

HPLC purity
99.18%
✓ Excellent
Excellent means 98% or higher.
In the vial
9.42 mgThe label says 10 mg, so 6% less.
Tested by
Uzorak
Tested on
See the certificate ↓

Confirmed on Uzorak's portal · checked Jun 24, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeC9MNC0

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.18%How much of what's in the vial is the target compound
Amount in the vial9.42 mglabel says 10 mg · 6% lessWhether you get the amount on the label
ContainerYellow caps
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 10 mg · Lab measured 9.42 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 6% less means in a syringe

94% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.4 mg using the measured mass, against 2.5 mg on the label — 6% less.

Certificate of analysis

Original document
Issued by Uzorak · Jun 24, 2026 · Batch Yellow caps

About this test

How this certificate was checked

Report numberC9MNC0
On the lab's portal✓ Confirmed Sep 9, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
What the portal showsThat the report is validUzorak's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Nova Labs' Trust Score until Jun 24, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 01 · Peptigrity team · filed Sep 9, 2026
Summary

Independent HPLC purity analysis of TB-500 from Nova Labs, performed by Uzorak on June 24, 2026. Reported purity: 99.18%. Net content: 9.42 mg against 10 mg labeled (94% of label). Batch Yellow caps. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

6 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?