Forumlongevatech.com - investigation · Shop talk · 4 replies

GHK-Cu 80mg lab test from Crush Research, November 2025

Freedom Diagnostics tested GHK-Cu 80mg from Crush Research on Nov 6, 2025. It measured 99.77% purity and 97.59 mg against 80 mg on the label.

HPLC purity
99.77%
✓ Excellent
Excellent means 98% or higher.
Amount measured
97.59 mgThe label says 80 mg, so 22% more.
Tested on
Lot
CRKL-80-1025-01
See the certificate ↓

Not checked on Freedom Diagnostics' portal

This certificate carries no lookup code. Freedom Diagnostics has a public portal, so a report with a code can be looked up there.

Freedom Diagnostics' site says: “Enter that code below and click Look up . The Search Code is always the first 4 characters of your company name followed by your accession number.”

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.77%How much of what's in the vial is the target compound
Amount measured97.59 mglabel says 80 mg · 22% moreWhether you get the amount on the label
Endotoxin≤ 0.05 EU/mLIs it safe to inject? Checks for bacterial toxins
ContainerTwo vials with dark blue caps, blue lyophilized powder (Crush Research Supply branded)
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 80 mg · Lab measured 97.59 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Certificate of analysis

Original document
Issued by Freedom Diagnostics · Nov 6, 2025 · Batch CRKL-80-1025-01

About this test

How this certificate was checked

Report numberCRKL-80-1025-01
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Crush Research's Trust Score until Nov 6, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Sample labelCrush Research Supply
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed May 8, 2026
Summary

Independent HPLC purity analysis of GHK-Cu/KPV/BPC-157/Thymosin Beta-4 from Crush Research, performed by Freedom Diagnostics on November 6, 2025. Reported purity: 99.77%. Net content: 97.59 mg against 80 mg labeled (122% of label). Tested content exceeds the labeled amount by 22%. Endotoxins: ≤ 0.05 EU/mL. Batch CRKL-80-1025-01. Sample source: shop-provided. Certificate of analysis attached.

Other lots of GHK-Cu from Crush Research

LotTestedLabPurityvs labelLab's portal
CR-GHK100MG-0828Aug 24, 2026ILS Laboratories99.59%102% of labelNot checked
CR-GHK50MG-0828Aug 24, 2026ILS Laboratories99.81%107% of labelNot checked
CR-GHK-100MG-2607-PurpleJul 31, 2026ILS Laboratories99.29%105% of labelNot checked
CR-GHK-50MG-2606-1Jun 26, 2026ILS Laboratories99.75%105% of labelNot checked
CR-GHKCU-100-2606-1Jun 9, 2026ILS Laboratories99.57%106% of labelNot checked
CRGHK-100-2604-1Apr 22, 2026ILS Laboratories99.91%105% of labelNot checked
CRKLO-80-2604-1Apr 22, 2026ILS Laboratories99.47%104% of labelNot checked
CR-GCU100-2603-1Apr 2, 2026BTLabs99.7%113% of labelLab has no portal

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.