TB-500 80mg lab test from EVO Labs Research, May 2026
Kovera Labs tested TB-500 80mg from EVO Labs Research on May 29, 2026. It measured 99.75% purity and 87.64 mg against 80 mg on the label.
- Amount measured
- 87.64 mgThe label says 80 mg, so 10% more.
- Tested by
- Kovera Labs
- Tested on
- Lot
- EVO5212026
Not checked on Kovera Labs' portal
This certificate carries no lookup code. Kovera Labs has a public portal, so a report with a code can be looked up there.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 456 TB-500 lab tests →TB-500 pricesEVO Labs Research reviews and all 58 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.75% | How much of what's in the vial is the target compound |
| Amount measured | 87.64 mglabel says 80 mg · 10% more | Whether you get the amount on the label |
| Container | Orange vial with silver crimp cap | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 80 mg · Lab measured 87.64 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
Certificate of analysis
About this test
How this certificate was checked
| Report number | EVO5212026 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validKovera Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward EVO Labs Research's Trust Score until May 29, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Jun 3, 2026 |
Independent HPLC purity analysis of TB-500/BPC-157/KPV/GHK-Cu from EVO Labs Research, performed by Kovera Labs on May 29, 2026. Reported purity: 99.75%. Net content: 87.64 mg against 80 mg labeled (110% of label). Batch EVO5212026. Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 454 other TB-500 tests on Peptigrity have a typical purity of 99.47%. This one is 99.75%.

Community discussion