Forumlongevatech.com - investigation · Shop talk · 4 replies

N-Acetyl Semax Amidate 50mg lab test from Uther, May 2026

Janoshik Labs tested N-Acetyl Semax Amidate 50mg from Uther on May 28, 2026. It measured 99.599% purity and 55.17 mg against 50 mg on the label.

HPLC purity
99.599%
✓ Excellent
Excellent means 98% or higher.
In the vial
55.17 mgThe label says 50 mg, so 10% more.
Tested by
Janoshik Labs
Tested on
Lot
NASX50-0508
See the certificate ↓

Confirmed on Janoshik Labs' portal · checked May 28, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeLLXTFP252QUH

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.599%How much of what's in the vial is the target compound
Amount in the vial55.17 mglabel says 50 mg · 10% moreWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 50 mg · Lab measured 55.17 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 10% more means in a syringe

110% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 13.8 mg using the measured mass, against 12.5 mg on the label — 10% more.

Certificate of analysis

Original document
Issued by Janoshik Labs · May 28, 2026 · Batch NASX50-0508

About this test

How this certificate was checked

Report number164334
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there.
Submitted viaShop panel (bulk upload)
Counts asOne lab testCounts toward Uther's Trust Score until May 28, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted by@uther 👑 Legend
Summary

Independent HPLC purity analysis of N-Acetyl Semax Amidate from Uther, performed by Janoshik Labs on May 28, 2026. Reported purity: 99.599%. Net content: 55.17 mg against 50 mg labeled (110% of label). Tested content exceeds the labeled amount by 10%. Batch NASX50-0508. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.