HomeLab Tests glowaminos peptides, Melanotan I (MT-1)
Purity · pass✓ Lab-verifiedShop-provided sample

Melanotan I (MT-1) × glowaminos peptides — lab test, May 2026

Lotlook this batch up across every shop →Check another lot
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
99.61%
Excellent purity only
↓ Download COA
Independently confirmed on the lab’s portal✓ Extra check

COA COA-2026-412627 matches ILS Laboratories's public record. So this test doesn't rest on our review alone — the lab confirms it too.

Lookup codeUQJ4JZ9

Test results

7 data points
Purity
99.61%
Endotoxins
Not tested
Heavy metals
ICP-MS: Arsenic 0.242 ppm, Cadmium Not Detected, Lead 0.1244 ppm, Mercury 0.286 ppm, Chromium 0.206 ppm — all Pass
Stated qty
10 mg
Tested qty
10.54 mg
Qty match
105% of labeled · +5%
Batch / Lot
GL-010129
COA number
COA-2026-412627
Tested by
ILS LaboratoriesView profile →

This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.

About this test

What’s in the vial

Label 10 mg · Lab measured 10.54 mg

105% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.6 mg using the measured mass, against 2.5 mg on the label — 5% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report numberCOA-2026-412627
Portal lookup✓ Lab-verified
Checked11 Aug 2026date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
PDF vs portalILS Laboratories's portal shows validity only
WeightCounts as one lab test

Independent HPLC purity analysis of Melanotan I (MT-1) from glowaminos peptides, performed by ILS Laboratories on May 30, 2026. Reported purity: 99.61%. Net content: 10.54 mg against 10 mg labeled (105% of label). Heavy metals: ICP-MS: Arsenic 0.242 ppm, Cadmium Not Detected, Lead 0.1244 ppm, Mercury 0.286 ppm, Chromium 0.206 ppm — all Pass. Batch GL-010129. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by ILS Laboratories · May 30, 2026 · Batch GL-010129

Other lots of Melanotan I (MT-1) from glowaminos peptides

LotTestedLabPurityvs labelStatus
GL-0101979 Jul 2026ILS Laboratories99.94%105%✓ Lab-verified
GL-01007118 Mar 2026freedomdiagnosticstesting.com99.655%119%✓ Lab-verified

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

The 143 other Melanotan I (MT-1) tests on Peptigrity range from 98.60% to 99.99%. This one sits at 99.61%.

More from glowaminos peptides
More Melanotan I (MT-1) tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.