Forumlongevatech.com - investigation · Shop talk · 4 replies

IGF-1 LR3 1mg lab test from Mile High Compounds, October 2025

Chromate tested IGF-1 LR3 1mg from Mile High Compounds on Oct 22, 2025. It measured 90.019% purity and 1.084 mg against 1 mg on the label.

HPLC purity
90.019%
⚠ Marginal
Marginal means 90% to 94.99%. Most research peptides are held to 95% or higher.
In the vial
1.084 mgThe label says 1 mg, so 8% more.
Tested by
Chromate
Tested on
Lot
IGF-001-MH-01
See the certificate ↓

Not checked on Chromate's portal

This certificate carries no lookup code. Chromate has a public portal, so a report with a code can be looked up there.

Chromate's site says: “Click 'Verify' (top right), then enter Job Number + Access Code from the COA”

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)90.019%How much of what's in the vial is the target compound
Amount in the vial1.084 mglabel says 1 mg · 8% moreWhether you get the amount on the label
Endotoxin0.0541 EU/mgIs it safe to inject? Checks for bacterial toxins
ContainerBlue cap with blue vial
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 1 mg · Lab measured 1.084 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 8% more means in a syringe

108% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 271 mcg using the measured mass, against 250 mcg on the label — 8% more.

Certificate of analysis

Original document
Issued by Chromate · Oct 22, 2025 · Batch IGF-001-MH-01

About this test

How this certificate was checked

Report numberIGF-001-MH-01
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validChromate's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Mile High Compounds' Trust Score until Oct 22, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Jun 3, 2026
Summary

Independent HPLC purity analysis of IGF-1 LR3 from Mile High Compounds, performed by Chromate on October 22, 2025. Reported purity: 90.019%. Purity falls below the 95% specification commonly applied to research peptides. Net content: 1.084 mg against 1 mg labeled (108% of label). Endotoxins: 0.0541 EU/mg. Batch IGF-001-MH-01. Sample source: shop-provided. Certificate of analysis attached.

Other lots of IGF-1 LR3 from Mile High Compounds

LotTestedLabPurityvs labelLab's portal
IGF-001-MH-02Feb 24, 2026Vanguard Laboratory98.89%100% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.