GHK-Cu 100mg lab test from Vertex Labs, April 2026
BTLabs tested GHK-Cu 100mg from Vertex Labs on Apr 14, 2026. It measured 99.7% purity and 68.1 mg against 100 mg on the label.
- In the vial
- 68.1 mgThe label says 100 mg, so 32% less.
- Tested by
- BTLabs
- Tested on
- Lot
- GH0000023
BTLabs has no public portal.
Only the lab can confirm this report, by email.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 904 GHK-Cu lab tests →GHK-Cu pricesVertex Labs reviews and all 25 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.7% | How much of what's in the vial is the target compound |
| Amount in the vial | 68.1 mglabel says 100 mg · 32% less | Whether you get the amount on the label |
| Container | Small clear vial; purple sample, white label, silver crimp, red plastic cap | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 100 mg · Lab measured 68.1 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 32% less means in a syringe
68% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 17 mg using the measured mass, against 25 mg on the label — 32% less.
Certificate of analysis
About this test
How this certificate was checked
| Report number | GH0000023 |
|---|---|
| On the lab's portal | Lab has no portalThis laboratory publishes no public lookup, so the report cannot be confirmed independently. |
| What the portal shows | That the report is validBTLabs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Vertex Labs' Trust Score until Apr 14, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Jul 7, 2026 |
Independent HPLC purity analysis of GHK-Cu from Vertex Labs, performed by BTLabs on April 14, 2026. Reported purity: 99.7%. Net content: 68.1 mg against 100 mg labeled (68% of label). Tested content is 32% below the labeled amount. Batch GH0000023. Sample source: shop-provided. Certificate of analysis attached.
Other lots of GHK-Cu from Vertex Labs
Related lab tests
The 902 other GHK-Cu tests on Peptigrity have a typical purity of 99.74%. This one is 99.7%.

Community discussion