GHK-Cu 50mg lab test from Tydes, November 2025
Janoshik Labs tested GHK-Cu 50mg from Tydes on Nov 5, 2025. It measured 99.65% purity and 69.15 mg against 50 mg on the label.
- In the vial
- 69.15 mgThe label says 50 mg, so 38% more.
- Tested by
- Janoshik Labs
- Tested on
- Lot
- GHK50102825
Not checked on Janoshik Labs' portal
This certificate carries no lookup code. Janoshik Labs has a public portal, so a report with a code can be looked up there.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 904 GHK-Cu lab tests →GHK-Cu pricesTydes reviews and all 56 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.65% | How much of what's in the vial is the target compound |
| Amount in the vial | 69.15 mglabel says 50 mg · 38% more | Whether you get the amount on the label |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 50 mg · Lab measured 69.15 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 38% more means in a syringe
138% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 17.3 mg using the measured mass, against 12.5 mg on the label — 38% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | GHK50102825 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Tydes' Trust Score until Nov 5, 2027. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Apr 29, 2026 |
Independent HPLC purity analysis of GHK-Cu from Tydes, performed by Janoshik Labs on November 5, 2025. Reported purity: 99.65%. Net content: 69.15 mg against 50 mg labeled (138% of label). Tested content exceeds the labeled amount by 38%. Batch GHK50102825. Sample source: shop-provided. Certificate of analysis attached.
Other lots of GHK-Cu from Tydes
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| GHKB100012226 | Jan 30, 2026 | Janoshik Labs | 99.743% | 108% of label | Not checked |
| GHB-1 | Jul 11, 2024 | Janoshik Labs | 99.864% | 101% of label | Not checked |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 902 other GHK-Cu tests on Peptigrity have a typical purity of 99.74%. This one is 99.65%.

Community discussion