Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

GHK-Cu 100mg lab test from Source Research, August 2026

ILS Laboratories tested GHK-Cu 100mg from Source Research on Aug 11, 2026. It measured 99.45% purity and 105.17 mg against 100 mg on the label.

HPLC purity
99.45%
✓ Excellent
Excellent means 98% or higher.
In the vial
105.17 mgThe label says 100 mg, so 5% more.
Tested on
Lot
sr-cu100-260720-002
See the certificate ↓

Confirmed on ILS Laboratories' portal · checked Aug 11, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup code9LHQQW29

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.45%How much of what's in the vial is the target compound
Amount in the vial105.17 mglabel says 100 mg · 5% moreWhether you get the amount on the label
Endotoxin0.089 EU/mLIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 100 mg · Lab measured 105.17 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 5% more means in a syringe

105% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 26.3 mg using the measured mass, against 25 mg on the label — 5% more.

Certificate of analysis

Original document
Issued by ILS Laboratories · Aug 11, 2026 · Batch sr-cu100-260720-002

About this test

How this certificate was checked

Report number-2026-LUYZFM
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validILS Laboratories' portal doesn't show the numbers, so they can't be compared there.
Submitted viaPeptigrity staff
Counts asOne lab testCounts toward Source Research's Trust Score until Aug 11, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted by@Peptigrity 👑 Legend
Summary

Independent HPLC purity analysis of GHK-Cu from Source Research, performed by ILS Laboratories on August 11, 2026. Reported purity: 99.45%. Net content: 105.17 mg against 100 mg labeled (105% of label). Endotoxins: 0.089 EU/mL. Batch sr-cu100-260720-002. Sample source: shop-provided. Certificate of analysis attached.

Other lots of GHK-Cu from Source Research

LotTestedLabPurityvs labelLab's portal
sr-ghkcu-260309-001May 11, 2026ILS Laboratories99.65%104% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

6 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.