GHK-Cu 100mg lab test from Puratek Peptides, June 2026
ILS Laboratories tested GHK-Cu 100mg from Puratek Peptides on Jun 11, 2026. It measured 99.72% purity and 104.42 mg against 100 mg on the label.
- In the vial
- 104.42 mgThe label says 100 mg, so 4% more.
- Tested by
- ILS Laboratories
- Tested on
- Lot
- GHK100004
Confirmed on ILS Laboratories' portal · checked Jun 11, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
YYGFDUV5Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 903 GHK-Cu lab tests →GHK-Cu pricesPuratek Peptides reviews and all 44 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.72% | How much of what's in the vial is the target compound |
| Amount in the vial | 104.42 mglabel says 100 mg · 4% more | Whether you get the amount on the label |
| Container | Lyophilized | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 100 mg · Lab measured 104.42 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 4% more means in a syringe
104% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 26.1 mg using the measured mass, against 25 mg on the label — 4% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | COA-2026-CIEHED |
|---|---|
| On the lab's portal | ✓ Confirmed Jul 31, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validILS Laboratories' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Puratek Peptides' Trust Score until Jun 11, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Jul 31, 2026 |
Independent HPLC purity analysis of GHK-Cu from Puratek Peptides, performed by ILS Laboratories on June 11, 2026. Reported purity: 99.72%. Net content: 104.42 mg against 100 mg labeled (104% of label). Batch GHK100004. Sample source: shop-provided. Certificate of analysis attached.
Other lots of GHK-Cu from Puratek Peptides
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| GHK50002 | Jun 1, 2026 | ILS Laboratories | 99.89% | 107% of label | ✓ Confirmed |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 901 other GHK-Cu tests on Peptigrity have a typical purity of 99.74%. This one is 99.72%.