GHK-Cu 50mg lab test from Peptidology, April 2025
Vanguard Laboratory tested GHK-Cu 50mg from Peptidology on Apr 2, 2025. It measured 99.5% purity and 53.15 mg against 50 mg on the label.
- In the vial
- 53.15 mgThe label says 50 mg, so 6% more.
- Tested by
- Vanguard Laboratory
- Tested on
- Lot
- 01-029-PD-1353
Not checked on Vanguard Laboratory's portal
This certificate carries no lookup code. Vanguard Laboratory has a public portal, so a report with a code can be looked up there.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 904 GHK-Cu lab tests →GHK-Cu pricesPeptidology reviews and all 123 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.5% | How much of what's in the vial is the target compound |
| Amount in the vial | 53.15 mglabel says 50 mg · 6% more | Whether you get the amount on the label |
| Container | Amber vial with brown cap | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 50 mg · Lab measured 53.15 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 6% more means in a syringe
106% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 13.3 mg using the measured mass, against 12.5 mg on the label — 6% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 01-029-PD-1353 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validVanguard Laboratory's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Peptidology's Trust Score until Apr 2, 2027. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Apr 20, 2026 |
Independent HPLC purity analysis of GHK-Cu from Peptidology, performed by Vanguard Laboratory on April 2, 2025. Reported purity: 99.5%. Net content: 53.15 mg against 50 mg labeled (106% of label). Batch 01-029-PD-1353. Sample source: shop-provided. Certificate of analysis attached.
Other lots of GHK-Cu from Peptidology
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| 1673 | Apr 14, 2026 | Vanguard Laboratory | 99.5% | 106% of label | Not checked |
| 1671 | Mar 10, 2026 | Vanguard Laboratory | 99.8% | 101% of label | Not checked |
| 1668 | Feb 24, 2026 | Vanguard Laboratory | 99.5% | 73% of label | Not checked |
| 1667 | Dec 1, 2025 | Vanguard Laboratory | 99.8% | 112% of label | Not checked |
| 1665 | Nov 18, 2025 | Vanguard Laboratory | 99.5% | 100% of label | Not checked |
| 1363 | Aug 28, 2025 | Vanguard Laboratory | 99.5% | 105% of label | Not checked |
| 1360 | Aug 11, 2025 | Vanguard Laboratory | 99% | 95% of label | Not checked |
| 01-029-PD-1358 | Jul 29, 2025 | Vanguard Laboratory | 99.72% | 130% of label | Not checked |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 902 other GHK-Cu tests on Peptigrity have a typical purity of 99.74%. This one is 99.5%.

Community discussion