GHK-Cu 50mg lab test from PADRE Research, July 2026
ILS Laboratories tested GHK-Cu 50mg from PADRE Research on Jul 24, 2026. It measured 99.87% purity and 52.81 mg against 50 mg on the label.
- In the vial
- 52.81 mgThe label says 50 mg, so 6% more.
- Tested by
- ILS Laboratories
- Tested on
- Lot
- PR-GHK50-B1-0626-1
Confirmed on ILS Laboratories' portal · checked Jul 24, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
9P7RQ546Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 903 GHK-Cu lab tests →GHK-Cu pricesPADRE Research reviews and all 4 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.87% | How much of what's in the vial is the target compound |
| Amount in the vial | 52.81 mglabel says 50 mg · 6% more | Whether you get the amount on the label |
| Heavy metals | Arsenic .032ppm Pass, Cadmium Not Detected Pass, Lead Not Detected Pass, Mercury Not Detected Pass, Chromium 1.637ppm Pass | Could there be metal contamination? |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 50 mg · Lab measured 52.81 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 6% more means in a syringe
106% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 13.2 mg using the measured mass, against 12.5 mg on the label — 6% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | COA-2026-3CMNOM |
|---|---|
| On the lab's portal | ✓ Confirmed Jul 27, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validILS Laboratories' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward PADRE Research's Trust Score until Jul 24, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Jul 27, 2026 |
Independent HPLC purity analysis of GHK-Cu from PADRE Research, performed by ILS Laboratories on July 24, 2026. Reported purity: 99.87%. Net content: 52.81 mg against 50 mg labeled (106% of label). Heavy metals: Arsenic .032ppm Pass, Cadmium Not Detected Pass, Lead Not Detected Pass, Mercury Not Detected Pass, Chromium 1.637ppm Pass. Batch PR-GHK50-B1-0626-1. Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 901 other GHK-Cu tests on Peptigrity have a typical purity of 99.74%. This one is 99.87%.

Community discussion