Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

GHK-Cu 50mg lab test from Orvella Labs, July 2026

Kovera Labs tested GHK-Cu 50mg from Orvella Labs on Jul 22, 2026. It measured 99.543% purity and 55.09 mg against 50 mg on the label.

HPLC purity
99.543%
✓ Excellent
Excellent means 98% or higher.
In the vial
55.09 mgThe label says 50 mg, so 10% more.
Tested by
Kovera Labs
Tested on
Lot
GHK-34N97
See the certificate ↓

Confirmed on Kovera Labs' portal · checked Jul 22, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeI78X4XM

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.543%How much of what's in the vial is the target compound
Amount in the vial55.09 mglabel says 50 mg · 10% moreWhether you get the amount on the label
Endotoxin≤ 0.5 EU/mL · passIs it safe to inject? Checks for bacterial toxins
Heavy metalsArsenic (As): Negative, Cadmium (Cd): Negative, Lead (Pb): Negative, Mercury (Hg): NegativeCould there be metal contamination?
ContainerLyophilized Powder / Purple Cap / Silver Crimp
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 50 mg · Lab measured 55.09 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 10% more means in a syringe

110% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 13.8 mg using the measured mass, against 12.5 mg on the label — 10% more.

Certificate of analysis

Original document
Issued by Kovera Labs · Jul 22, 2026 · Batch GHK-34N97

About this test

How this certificate was checked

Report numberKVR-2026-3EB899
On the lab's portal✓ Confirmed Aug 26, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
What the portal showsThat the report is validKovera Labs' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Orvella Labs' Trust Score until Jul 22, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Sample labelorvellalab peptides
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Aug 26, 2026
Summary

Independent HPLC purity analysis of GHK-Cu from Orvella Labs, performed by Kovera Labs on July 22, 2026. Reported purity: 99.543%. Net content: 55.09 mg against 50 mg labeled (110% of label). Tested content exceeds the labeled amount by 10%. Endotoxins: ≤0.5 EU/mL Pass. Heavy metals: Arsenic (As): Negative, Cadmium (Cd): Negative, Lead (Pb): Negative, Mercury (Hg): Negative. Batch GHK-34N97. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

6 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.