Forumlongevatech.com - investigation · Shop talk · 4 replies

GHK-Cu 1mg lab test from Nexaph, February 2026

Janoshik Labs tested GHK-Cu 1mg from Nexaph on Feb 27, 2026. It measured 99.186% purity and 0.84 mg against 1 mg on the label.

HPLC purity
99.186%
✓ Excellent
Excellent means 98% or higher.
In the vial
0.84 mgThe label says 1 mg, so 16% less.
Tested by
Janoshik Labs
Tested on
Lot
AHK102202​2026-02
See the certificate ↓

Not checked on Janoshik Labs' portal

This certificate carries no lookup code. Janoshik Labs has a public portal, so a report with a code can be looked up there.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.186%How much of what's in the vial is the target compound
Amount in the vial0.84 mglabel says 1 mg · 16% lessWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 1 mg · Lab measured 0.84 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 16% less means in a syringe

84% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 210 mcg using the measured mass, against 250 mcg on the label — 16% less.

Certificate of analysis

Original document
Issued by Janoshik Labs · Feb 27, 2026 · Batch AHK102202​2026-02

About this test

How this certificate was checked

Report numberAHK102202​2026-02
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Nexaph's Trust Score until Feb 27, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Apr 6, 2026
Summary

Independent HPLC purity analysis of GHK-Cu from Nexaph, performed by Janoshik Labs on February 27, 2026. Reported purity: 99.186%. Net content: 0.84 mg against 1 mg labeled (84% of label). Tested content is 16% below the labeled amount. Batch AHK102202​2026-02. Sample source: shop-provided. Certificate of analysis attached.

Other lots of GHK-Cu from Nexaph

LotTestedLabPurityvs labelLab's portal
GHK500228​2026-13Mar 10, 2026Janoshik Labs99.893%109% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.