Forumlongevatech.com - investigation · Shop talk · 4 replies

CJC-1295 with DAC lab test from Synerium Peptides, July 2026

Uzorak tested CJC-1295 with DAC from Synerium Peptides on Jul 2, 2026. It measured 99.91% purity and 5.57 mg against 5 mg on the label.

HPLC purity
99.91%
✓ Excellent
Excellent means 98% or higher.
In the vial
5.57 mgThe label says 5 mg, so 11% more.
Tested by
Uzorak
Tested on
Lot
Sr-202601-007
See the certificate ↓

Confirmed on Uzorak's portal · checked Jul 2, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeD70-W90

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.91%How much of what's in the vial is the target compound
Amount in the vial5.57 mglabel says 5 mg · 11% moreWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 5 mg · Lab measured 5.57 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 11% more means in a syringe

111% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.4 mg using the measured mass, against 1.3 mg on the label — 11% more.

Certificate of analysis

Original document
Issued by Uzorak · Jul 2, 2026 · Batch Sr-202601-007

About this test

How this certificate was checked

Report numberD70-W90
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validUzorak's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Synerium Peptides' Trust Score until Jul 2, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 01 · Peptigrity team · filed Oct 27, 2026
Summary

Independent HPLC purity analysis of CJC-1295 with DAC from Synerium Peptides, performed by Uzorak on July 2, 2026. Reported purity: 99.91%. Net content: 5.57 mg against 5 mg labeled (111% of label). Tested content exceeds the labeled amount by 11%. Batch Sr-202601-007. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.