BPC-157 10mg lab test from Research Chem HQ, October 2024
Chromate tested BPC-157 10mg from Research Chem HQ on Oct 30, 2024. It measured 98.242% purity and 10.78 mg against 10 mg on the label.
⚠ This test is older than 2 years - results may not reflect current product quality.
- In the vial
- 10.78 mgThe label says 10 mg, so 8% more.
- Tested by
- Chromate
- Tested on
- Lot
- #001
Confirmed on Chromate's portal · checked Oct 30, 2024
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
RCHQEJHR98C6Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 955 BPC-157 lab tests →BPC-157 pricesResearch Chem HQ reviews and all 91 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 98.242% | How much of what's in the vial is the target compound |
| Amount in the vial | 10.78 mglabel says 10 mg · 8% more | Whether you get the amount on the label |
| Container | White Lyophilized Powder | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 10 mg · Lab measured 10.78 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 8% more means in a syringe
108% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.7 mg using the measured mass, against 2.5 mg on the label — 8% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | #21958 |
|---|---|
| On the lab's portal | ✓ Confirmed Jul 16, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validChromate's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testOlder than 2 years · not counted in the Trust Score |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Jul 16, 2026 |
Independent HPLC purity analysis of BPC-157 from Research Chem HQ, performed by Chromate on October 30, 2024. Reported purity: 98.242%. Net content: 10.78 mg against 10 mg labeled (108% of label). Batch #001. Sample source: shop-provided. Certificate of analysis attached.
Other lots of BPC-157 from Research Chem HQ
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| #HX4RRT | Jun 4, 2026 | ILS Laboratories | 99.8% | 103% of label | ✓ Confirmed |
| 8KJ3P | Mar 22, 2026 | Kovera Labs | 99.934% | 118% of label | ✓ Confirmed |
| R34N8 | Jan 29, 2026 | Vanguard Laboratory | 99.8% | 106% of label | Not checked |
| 007 | Aug 5, 2025 | Vanguard Laboratory | 99.48% | 109% of label | Not checked |
| #008 | Jun 25, 2025 | Chromate | 99.833% | 119% of label | ✓ Confirmed |
| #005 | Apr 25, 2025 | Chromate | 99.519% | 99% of label | ✓ Confirmed |
| #004 | Mar 8, 2025 | Chromate | 98.225% | 90% of label | ✓ Confirmed |
| #003 | Feb 19, 2025 | Chromate | 98.516% | 100% of label | ✓ Confirmed |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 952 other BPC-157 tests on Peptigrity have a typical purity of 99.48%. This one is 98.242%.

Community discussion