Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

BPC-157 lab test from Rivn Research Peptides, November 2026

Freedom Diagnostics tested BPC-157 from Rivn Research Peptides on Nov 7, 2026. It measured 99.1% purity and 12.4 mg against 10 mg on the label.

HPLC purity
99.1%
✓ Excellent
Excellent means 98% or higher.
In the vial
12.4 mgThe label says 10 mg, so 24% more.
Tested on
Sterility
✓ Pass · no growth
Content uniformity
✓ Pass
Lot
342
See the certificate ↓

Confirmed on Freedom Diagnostics' portal · checked Nov 7, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeRivn2611041468

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.1%How much of what's in the vial is the target compound
Amount in the vial12.4 mglabel says 10 mg · 24% moreWhether you get the amount on the label
EndotoxinPassIs it safe to inject? Checks for bacterial toxins
Heavy metalsPass — Arsenic, Cadmium, Lead and Mercury below limitsCould there be metal contamination?
SterilityPass — no growthIs it safe to inject? Checks for live bacteria or fungi
Content uniformityPass

This certificate covers purity, quantity, endotoxins, sterility, heavy metals and content uniformity.

What’s in the vial

Label 10 mg · Lab measured 12.4 mg

Several vials from this lot were tested; none of them was yours. This page reports what the certificate says; it does not recommend a dose.

What 24% more means in a syringe

124% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 3.1 mg using the measured mass, against 2.5 mg on the label — 24% more.

Certificate of analysis

Original document
Issued by Freedom Diagnostics · Nov 7, 2026 · Batch 342

About this test

How this certificate was checked

Report number2611041468
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there.
Submitted viaShop panel (bulk upload)
Counts asOne lab testCounts toward Rivn Research Peptides' Trust Score until Nov 7, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted by@officialrivnresearch 👑 Legend
Summary

Independent HPLC purity analysis of BPC-157 from Rivn Research Peptides, performed by Freedom Diagnostics on November 7, 2026. Reported purity: 99.1%. Net content: 12.4 mg against 10 mg labeled (124% of label). Tested content exceeds the labeled amount by 24%. Endotoxins: Pass. Sterility: passed. Content uniformity: passed. Heavy metals: Pass — Arsenic, Cadmium, Lead and Mercury below limits. Batch 342. Sample source: shop-provided. Certificate of analysis attached.

Other lots of BPC-157 from Rivn Research Peptides

LotTestedLabPurityvs labelLab's portal
7831Apr 5, 2026Freedom Diagnostics99.194%96% of labelNot checked
3827Feb 18, 2026Freedom Diagnostics99.15%90% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

6 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.