BPC-157 5mg lab test from Modified Aminos, April 2026
Vanguard Laboratory tested BPC-157 5mg from Modified Aminos on Apr 20, 2026. It measured 99.8% purity and 4.1 mg against 5 mg on the label.
- In the vial
- 4.1 mgThe label says 5 mg, so 18% less.
- Tested by
- Vanguard Laboratory
- Tested on
- Lot
- MA-BPCP-51
Not checked on Vanguard Laboratory's portal
This certificate carries no lookup code. Vanguard Laboratory has a public portal, so a report with a code can be looked up there.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 955 BPC-157 lab tests →BPC-157 pricesModified Aminos reviews and all 71 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.8% | How much of what's in the vial is the target compound |
| Amount in the vial | 4.1 mglabel says 5 mg · 18% less | Whether you get the amount on the label |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 5 mg · Lab measured 4.1 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 18% less means in a syringe
82% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1 mg using the measured mass, against 1.3 mg on the label — 18% less.
Certificate of analysis
About this test
How this certificate was checked
| Report number | V260326-16 012 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validVanguard Laboratory's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Modified Aminos' Trust Score until Apr 20, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Jul 13, 2026 |
Independent HPLC purity analysis of BPC-157 from Modified Aminos, performed by Vanguard Laboratory on April 20, 2026. Reported purity: 99.8%. Net content: 4.1 mg against 5 mg labeled (82% of label). Tested content is 18% below the labeled amount. Batch MA-BPCP-51. Sample source: shop-provided. Certificate of analysis attached.
Other lots of BPC-157 from Modified Aminos
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| MA-BPCS-101 | Mar 22, 2026 | Ethos Analytics | — | 109% of label | Not checked |
| MA-BPCS-100 | Mar 22, 2026 | Ethos Analytics | — | 107% of label | Not checked |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 952 other BPC-157 tests on Peptigrity have a typical purity of 99.47%. This one is 99.8%.