COA 2606080673 matches freedomdiagnosticstesting.com's public record. So this test doesn't rest on our review alone — the lab confirms it too.
MRP2606080673This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.
Label 25 mg · Lab measured 21.02 mg
84% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 5.3 mg using the measured mass, against 6.3 mg on the label — 16% less.
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
| Report number | 2606080673 |
|---|---|
| Portal lookup | ✓ Lab-verified |
| Checked | 14 Jul 2026date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| PDF vs portal | freedomdiagnosticstesting.com's portal shows validity only |
| Weight | Counts as one lab test |
Independent HPLC purity analysis of BPC-157 from modernresearchpeptides.net, performed by freedomdiagnosticstesting.com on June 10, 2026. Reported purity: 99.61%. Net content: 21.02 mg against 25 mg labeled (84% of label). Tested content is 16% below the labeled amount. Batch Z3-6737. Sample source: shop-provided. Certificate of analysis attached.
| Lot | Tested | Lab | Purity | vs label | Status |
|---|---|---|---|---|---|
| EMH57102 | 2 Apr 2026 | freedomdiagnosticstesting.com | 99.19% | 107% | ✓ Lab-verified |
| NHK57A | 27 Mar 2026 | freedomdiagnosticstesting.com | 99.2% | 126% | ✓ Lab-verified |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.