HomeLab Tests Biolabshop, BPC-157
Purity · passShop-provided sample

BPC-157 × Biolabshop — lab test, June 2024

Lotlook this batch up across every shop →Check another lot
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
⚠ This test is older than 2 years - results may not reflect current product quality.
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
97%
Research grade purity only
↓ Download COA
Independent verification available

Analiza Białek publishes a public verification portal. Any test attributed to this lab can be looked up and confirmed directly with the lab — so this result doesn't rest on our review alone. Look up by order number and password

This certificate carries no lookup code.

Test results

7 data points
Purity
97%
Endotoxins
Not tested
Heavy metals
Not tested
Stated qty
5 mg
Tested qty
5.35 mg
Qty match
107% of labeled · +7%
Batch / Lot
100005290
Container
White powder in glass vial; dark blue cap vial shown in photo with branded box
Tested by
Analiza BiałekView profile →

This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.

About this test

What’s in the vial

Label 5 mg · Lab measured 5.35 mg

107% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.3 mg using the measured mass, against 1.3 mg on the label — 7% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Independent HPLC purity analysis of BPC-157 from Biolabshop, performed by Analiza Białek on June 21, 2024. Reported purity: 97%. Net content: 5.35 mg against 5 mg labeled (107% of label). Batch 100005290. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by Analiza Białek · Jun 21, 2024 · Batch 100005290

Other lots of BPC-157 from Biolabshop

LotTestedLabPurityvs labelStatus
10000868116 Jul 2025Analiza Białek98%104%Unverified
10000867716 Jul 2025Analiza Białek98%106%Unverified
10000760817 Apr 2025Analiza Białek98%109%Unverified
10000529025 Jun 2024Analiza Białek97%107%Unverified

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

The 874 other BPC-157 tests on Peptigrity range from 91.65% to 100.00%. This one sits at 97.00%.

More from Biolabshop
More BPC-157 tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.