BPC-157 10mg lab test from BioEdge Research Labs, February 2026
MDx BioAnalytical Laboratory tested BPC-157 10mg from BioEdge Research Labs on Feb 17, 2026. It measured 99.77% purity and 10.87 mg against 10 mg on the label.
- In the vial
- 10.87 mgThe label says 10 mg, so 9% more.
- Tested by
- MDx BioAnalytical Laboratory
- Tested on
- Lot
- BPC1001212026-18
Confirmed on MDx BioAnalytical Laboratory's portal · checked Feb 17, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
260750Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 955 BPC-157 lab tests →BPC-157 pricesBioEdge Research Labs reviews and all 104 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.77% | How much of what's in the vial is the target compound |
| Amount in the vial | 10.87 mglabel says 10 mg · 9% more | Whether you get the amount on the label |
| Endotoxin | ≤ 0.05 EU/mL · pass | Is it safe to inject? Checks for bacterial toxins |
| Container | White Crystals | |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 10 mg · Lab measured 10.87 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 9% more means in a syringe
109% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.7 mg using the measured mass, against 2.5 mg on the label — 9% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 260750 |
|---|---|
| On the lab's portal | ✓ Confirmed Aug 14, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validMDx BioAnalytical Laboratory's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward BioEdge Research Labs' Trust Score until Feb 17, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Aug 14, 2026 |
Independent HPLC purity analysis of BPC-157 from BioEdge Research Labs, performed by MDx BioAnalytical Laboratory on February 17, 2026. Reported purity: 99.77%. Net content: 10.87 mg against 10 mg labeled (109% of label). Endotoxins: PASS (≤0.05 EU/mL). Batch BPC1001212026-18. Sample source: shop-provided. Certificate of analysis attached.
Other lots of BPC-157 from BioEdge Research Labs
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| 062026BPC10 | Aug 3, 2026 | Kovera Labs | 99.751% | 124% of label | ✓ Confirmed |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 952 other BPC-157 tests on Peptigrity have a typical purity of 99.47%. This one is 99.77%.

Community discussion