Forumlongevatech.com - investigation · Shop talk · 4 replies

BPC-157 10mg lab test from Atomik Labz, August 2025

Vanguard Laboratory tested BPC-157 10mg from Atomik Labz on Aug 28, 2025. It measured 99.01% purity and 11.1 mg against 10 mg on the label.

HPLC purity
99.01%
✓ Excellent
Excellent means 98% or higher.
In the vial
11.1 mgThe label says 10 mg, so 11% more.
Tested on
Lot
N80525N
See the certificate ↓

Not checked on Vanguard Laboratory's portal

This certificate carries no lookup code. Vanguard Laboratory has a public portal, so a report with a code can be looked up there.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.01%How much of what's in the vial is the target compound
Amount in the vial11.1 mglabel says 10 mg · 11% moreWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 10 mg · Lab measured 11.1 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 11% more means in a syringe

111% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.8 mg using the measured mass, against 2.5 mg on the label — 11% more.

Certificate of analysis

Original document
Issued by Vanguard Laboratory · Aug 28, 2025 · Batch N80525N

About this test

How this certificate was checked

Report numberN80525N
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validVanguard Laboratory's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Atomik Labz's Trust Score until Aug 28, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Apr 17, 2026
Summary

Independent HPLC purity analysis of BPC-157 from Atomik Labz, performed by Vanguard Laboratory on August 28, 2025. Reported purity: 99.01%. Net content: 11.1 mg against 10 mg labeled (111% of label). Tested content exceeds the labeled amount by 11%. Batch N80525N. Sample source: shop-provided. Certificate of analysis attached.

Other lots of BPC-157 from Atomik Labz

LotTestedLabPurityvs labelLab's portal
B1022726Mar 5, 2026BioRegen99.76%102% of labelNot checked
N1024NNov 11, 2025Janoshik Labs99.584%121% of labelNot checked
C0521CJun 29, 2025Vanguard Laboratory99.39%118% of labelNot checked
NN03172Mar 21, 2025Janoshik Labs99.47%114% of labelNot checked
FF1223Dec 31, 2024Janoshik Labs99.64%114% of labelNot checked
HH120324Dec 15, 2024Janoshik Labs99.362%122% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

7 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.