Forumlongevatech.com - investigation · Shop talk · 4 replies

BPC-157 10mg lab test from Limitless Biotech, October 3, 2025

Janoshik Labs tested BPC-157 10mg from Limitless Biotech on Oct 3, 2025. It measured 95.407% purity and 10.69 mg against 10 mg on the label.

HPLC purity
95.407%
◆ Research grade
Research grade means 95% to 97.99%.
In the vial
10.69 mgThe label says 10 mg, so 7% more.
Tested by
Janoshik Labs
Tested on
Lot
1299
See the certificate ↓

Not checked on Janoshik Labs' portal

This certificate carries no lookup code. Janoshik Labs has a public portal, so a report with a code can be looked up there.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)95.407%How much of what's in the vial is the target compound
Amount in the vial10.69 mglabel says 10 mg · 7% moreWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 10 mg · Lab measured 10.69 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 7% more means in a syringe

107% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.7 mg using the measured mass, against 2.5 mg on the label — 7% more.

Certificate of analysis

Original document
Issued by Janoshik Labs · Oct 3, 2025 · Batch 1299

About this test

How this certificate was checked

Report number1299
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Limitless Biotech's Trust Score until Oct 3, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed May 26, 2026
Summary

Independent HPLC purity analysis of BPC-157 Acetate from Limitless Biotech, performed by Janoshik Labs on October 3, 2025. Reported purity: 95.407%. Net content: 10.69 mg against 10 mg labeled (107% of label). Batch 1299. Sample source: shop-provided. Certificate of analysis attached.

Other lots of BPC-157 from Limitless Biotech

LotTestedLabPurityvs labelLab's portal
1333Apr 10, 2026TrustPointe Analytics99.027%110% of labelNot checked
1331Mar 10, 2026TrustPointe Analytics99.719%93% of labelNot checked
1330 vial 2Mar 9, 2026TrustPointe Analytics99.99%119% of labelNot checked
1299Oct 3, 2025Janoshik Labs99.407%102% of labelNot checked
1305Sep 11, 2025TrustPointe Analytics99.817%92% of labelNot checked
1217Aug 29, 2025TrustPointe Analytics99.78%97% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.