Forumlongevatech.com - investigation · Shop talk · 4 replies

BPC-157 40mg lab test from 24Peptides, May 2026

liquilabs tested BPC-157 40mg from 24Peptides on May 4, 2026. It measured 99.7% purity and 39.8 mg against 40 mg on the label.

HPLC purity
99.7%
✓ Excellent
Excellent means 98% or higher.
In the vial
39.8 mgThe label says 40 mg, so 1% less.
Tested by
liquilabs
Tested on
Lot
GF-BPC40-B241
See the certificate ↓

liquilabs has no public portal.

Only the lab can confirm this report, by email.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.7%How much of what's in the vial is the target compound
Amount in the vial39.8 mglabel says 40 mg · 1% lessWhether you get the amount on the label
Endotoxin< 0.001 EU/mgIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 40 mg · Lab measured 39.8 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 1% less means in a syringe

99% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 10 mg using the measured mass, against 10 mg on the label — 1% less.

Certificate of analysis

Original document
Issued by liquilabs · May 4, 2026 · Batch GF-BPC40-B241

About this test

How this certificate was checked

Report numberGF-BPC40-B241
On the lab's portalLab has no portalThis laboratory publishes no public lookup, so the report cannot be confirmed independently.
What the portal showsThat the report is validliquilabs' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward 24Peptides' Trust Score until May 4, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Jun 24, 2026
Summary

Independent HPLC purity analysis of BPC-157 from 24Peptides, performed by liquilabs on May 4, 2026. Reported purity: 99.7%. Net content: 39.8 mg against 40 mg labeled (99% of label). Endotoxins: < 0.001 EU/mg. Batch GF-BPC40-B241. Sample source: shop-provided. Certificate of analysis attached.

Other lots of BPC-157 from 24Peptides

LotTestedLabPurityvs labelLab's portal
GF-BPCTB5-B241Jun 22, 2026liquilabs99.5%135% of labelLab has no portal
GF-BPCTB10-B241Jun 11, 2026liquilabs99.8%147% of labelLab has no portal
GF-KLOW-B242May 26, 2026liquilabs99.4%126% of labelLab has no portal
GF-BPC20-B242May 4, 2026liquilabs99.8%102% of labelLab has no portal
GF-BPC10-B241Feb 16, 2026liquilabs99.8%107% of labelLab has no portal
GF112025085Feb 16, 2026liquilabs99.3%130% of labelLab has no portal
GF092025045Jan 27, 2026liquilabs99.8%122% of labelLab has no portal
GF122025103Jan 27, 2026liquilabs99.8%116% of labelLab has no portal

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.