HomeLab Tests Peptide Plugs, ARA-290
Purity · pass✓ Lab-verifiedShop-provided sample

ARA-290 × Peptide Plugs — lab test, June 2026

Lotlook this batch up across every shop →Check another lot
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
99.82%
Excellent purity only
↓ Download COA
Independently confirmed on the lab’s portal✓ Extra check

COA 2606120660 matches freedomdiagnosticstesting.com's public record. So this test doesn't rest on our review alone — the lab confirms it too.

Lookup codePept2606120660

Test results

8 data points
Purity
99.82%
Endotoxins
Not tested
Heavy metals
Fentanyl Screen: Negative
Stated qty
10 mg
Tested qty
10.43 mg
Qty match
104% of labeled · +4%
Batch / Lot
142-01-DK
COA number
2606120660
Container
White Lyophilized Powder
Tested by

This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.

About this test

What’s in the vial

Label 10 mg · Lab measured 10.43 mg

104% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.6 mg using the measured mass, against 2.5 mg on the label — 4% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report number2606120660
Portal lookup✓ Lab-verified
Checked27 Aug 2026date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
PDF vs portalfreedomdiagnosticstesting.com's portal shows validity only
WeightCounts as one lab test

Independent HPLC purity analysis of ARA-290 from Peptide Plugs, performed by freedomdiagnosticstesting.com on June 15, 2026. Reported purity: 99.82%. Net content: 10.43 mg against 10 mg labeled (104% of label). Heavy metals: Fentanyl Screen: Negative. Batch 142-01-DK. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by freedomdiagnosticstesting.com · Jun 15, 2026 · Batch 142-01-DK

Related lab tests

8 tests

The 92 other ARA-290 tests on Peptigrity range from 53.90% to 99.99%. This one sits at 99.82%.

More from Peptide Plugs
More ARA-290 tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.