Forumlongevatech.com - investigation · Shop talk · 4 replies

ARA-290 16mg lab test from Liberty Peptides, January 2026

Bioviridian tested ARA-290 16mg from Liberty Peptides on Jan 28, 2026. It measured 99.4% purity and 17 mg against 16 mg on the label.

HPLC purity
99.4%
✓ Excellent
Excellent means 98% or higher.
In the vial
17 mgThe label says 16 mg, so 6% more.
Tested by
Bioviridian
Tested on
Lot
LPUS3012
See the certificate ↓

Not checked on Bioviridian's portal

This certificate carries no lookup code. Bioviridian has a public portal, so a report with a code can be looked up there.

Bioviridian's site says: “Enter the COA number from your results email to view, download or print your Certificate of Analysis.”

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.4%How much of what's in the vial is the target compound
Amount in the vial17 mglabel says 16 mg · 6% moreWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 16 mg · Lab measured 17 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 6% more means in a syringe

106% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 4.3 mg using the measured mass, against 4 mg on the label — 6% more.

Certificate of analysis

Original document
Issued by Bioviridian · Jan 28, 2026 · Batch LPUS3012

About this test

How this certificate was checked

Report numberLPUS3012
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validBioviridian's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Liberty Peptides' Trust Score until Jan 28, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Apr 13, 2026
Summary

Independent HPLC purity analysis of ARA-290 from Liberty Peptides, performed by Bioviridian on January 28, 2026. Reported purity: 99.4%. Net content: 17 mg against 16 mg labeled (106% of label). Batch LPUS3012. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →