ARA-290 5mg lab test from Biolabshop, March 2025
Analiza Białek tested ARA-290 5mg from Biolabshop on Mar 11, 2025. It measured 98% purity and 5.56 mg against 5 mg on the label.
- In the vial
- 5.56 mgThe label says 5 mg, so 11% more.
- Tested by
- Analiza Białek
- Tested on
- Lot
- 100007018
Not checked on Analiza Białek's portal
This certificate carries no lookup code. Analiza Białek has a public portal, so a report with a code can be looked up there.
Analiza Białek's site says: “Look up by order number and password”
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 106 ARA-290 lab tests →ARA-290 pricesBiolabshop reviews and all 69 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 98% | How much of what's in the vial is the target compound |
| Amount in the vial | 5.56 mglabel says 5 mg · 11% more | Whether you get the amount on the label |
| Container | White powder in glass vial; dark blue cap vial shown in photo with branded box | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 5 mg · Lab measured 5.56 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 11% more means in a syringe
111% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.4 mg using the measured mass, against 1.3 mg on the label — 11% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 100007018 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validAnaliza Białek's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Biolabshop's Trust Score until Mar 11, 2027. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Mar 30, 2026 |
Independent HPLC purity analysis of ARA-290 from Biolabshop, performed by Analiza Białek on March 11, 2025. Reported purity: 98%. Net content: 5.56 mg against 5 mg labeled (111% of label). Tested content exceeds the labeled amount by 11%. Batch 100007018. Sample source: shop-provided. Certificate of analysis attached.