ARA-290 16mg lab test from American Peptides, July 2026

Bioviridian tested ARA-290 16mg from American Peptides on Jul 7, 2026. It measured 99.9% purity and 16.39 mg against 16 mg on the label.

HPLC purity
99.9%
✓ Excellent
Excellent means 98% or higher.
In the vial
16.39 mgThe label says 16 mg, so 2% more.
Tested by
Bioviridian
Tested on
Lot
ARA290-0616
See the certificate ↓

Not checked on Bioviridian's portal

This certificate carries no lookup code. Bioviridian has a public portal, so a report with a code can be looked up there.

Bioviridian's site says: “Enter the COA number from your results email to view, download or print your Certificate of Analysis.”

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.9%How much of what's in the vial is the target compound
Amount in the vial16.39 mglabel says 16 mg · 2% moreWhether you get the amount on the label
Endotoxin< 0.05 EU/mLIs it safe to inject? Checks for bacterial toxins
Heavy metals<0.01 ppmCould there be metal contamination?
ContainerWhite lyophilized powder
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 16 mg · Lab measured 16.39 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 2% more means in a syringe

102% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 4.1 mg using the measured mass, against 4 mg on the label — 2% more.

Certificate of analysis

Original document
Issued by Bioviridian · Jul 7, 2026 · Batch ARA290-0616

About this test

How this certificate was checked

Report numberCOA5630
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validBioviridian's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward American Peptides' Trust Score until Jul 7, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Jul 22, 2026
Summary

Independent HPLC purity analysis of ARA-290 from American Peptides, performed by Bioviridian on July 7, 2026. Reported purity: 99.9%. Net content: 16.39 mg against 16 mg labeled (102% of label). Endotoxins: <0.05 EU/mL. Heavy metals: <0.01 ppm. Batch ARA290-0616. Sample source: shop-provided. Certificate of analysis attached.