5-Amino-1MQ lab test from Voltera Sciences Peptides, May 2026
Kovera Labs tested 5-Amino-1MQ from Voltera Sciences Peptides on May 14, 2026. It measured 99.887% purity and 10.87 mg against 10 mg on the label.
- In the vial
- 10.87 mgThe label says 10 mg, so 9% more.
- Tested by
- Kovera Labs
- Tested on
- Lot
- 5AMINO.05.02.2026
Confirmed on Kovera Labs' portal · checked May 14, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
TCGQE44Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 196 5-Amino-1MQ lab tests →5-Amino-1MQ pricesVoltera Sciences Peptides reviews and all 20 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.887% | How much of what's in the vial is the target compound |
| Amount in the vial | 10.87 mglabel says 10 mg · 9% more | Whether you get the amount on the label |
| Endotoxin | < 0.5 EU/mL · pass | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Arsenic Negative, Cadmium Negative, Lead Negative, Mercury Negative - all PASS | Could there be metal contamination? |
| Container | Transparent Cap / Bronze Crimp / Lyophilized powder | |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.
What’s in the vial
Label 10 mg · Lab measured 10.87 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 9% more means in a syringe
109% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.7 mg using the measured mass, against 2.5 mg on the label — 9% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | TCGQE44 |
|---|---|
| On the lab's portal | ✓ Confirmed Jul 14, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validKovera Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Voltera Sciences Peptides' Trust Score until May 14, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Jul 14, 2026 |
Independent HPLC purity analysis of 5-Amino-IMQ from Voltera Sciences Peptides, performed by Kovera Labs on May 14, 2026. Reported purity: 99.887%. Net content: 10.87 mg against 10 mg labeled (109% of label). Endotoxins: <0.5 EU/mL PASS. Heavy metals: Arsenic Negative, Cadmium Negative, Lead Negative, Mercury Negative - all PASS. Batch 5AMINO.05.02.2026. Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 194 other 5-Amino-1MQ tests on Peptigrity have a typical purity of 99.73%. This one is 99.887%.

Community discussion