HomeLab Tests vertexpeptideslab.org, 5-Amino-1MQ
Purity · passLab has no portalShop-provided sample

5-Amino-1MQ × vertexpeptideslab.org — lab test, April 2026

Sample label: Vertex Labs
Lotlook this batch up across every shop →Check another lot
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
99.3%
Excellent purity only
↓ Download COA
COA on file — not portal-verified

This lab doesn't publish a public lookup, so we can't confirm the certificate against the lab's own record. The document was reviewed before publication, but it rests on our review alone.

What portal verification means →

Test results

7 data points
Purity
99.3%
Endotoxins
Not tested
Heavy metals
Not tested
Stated qty
10 mg
Tested qty
14.4 mg
Qty match
144% of labeled · +44%
Batch / Lot
AM000042
Container
Small clear vial; orange sample, white label, silver crimp, black plastic cap
Tested by
BTLabsView profile →

This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.

About this test

What’s in the vial

Label 10 mg · Lab measured 14.4 mg

144% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 3.6 mg using the measured mass, against 2.5 mg on the label — 44% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report numberAM000042
Portal lookupLab has no portalThis laboratory publishes no public lookup, so the report cannot be confirmed independently.
PDF vs portalBTLabs's portal shows validity only
WeightCounts as one lab test

Independent HPLC purity analysis of 5-Amino-IMQ from vertexpeptideslab.org, performed by BTLabs on April 24, 2026. Reported purity: 99.3%. Net content: 14.4 mg against 10 mg labeled (144% of label). Tested content exceeds the labeled amount by 44%. Batch AM000042. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by BTLabs · Apr 24, 2026 · Batch AM000042

Related lab tests

8 tests

The 182 other 5-Amino-1MQ tests on Peptigrity range from 95.29% to 99.99%. This one sits at 99.30%.

More from vertexpeptideslab.org
More 5-Amino-1MQ tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.