Thymalin lab test from Midshire Labs (formerly Regen Peptides), December 2025
Janoshik Labs tested Thymalin from Midshire Labs (formerly Regen Peptides) on Dec 2, 2025. It measured 99.525% purity and 26.66 mg against 20 mg on the label.
- In the vial
- 26.66 mgThe label says 20 mg, so 33% more.
- Tested by
- Janoshik Labs
- Tested on
- Lot
- THYMU20-1121
Not checked on Janoshik Labs' portal
This certificate carries no lookup code. Janoshik Labs has a public portal, so a report with a code can be looked up there.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 47 Thymalin lab tests →Thymalin pricesMidshire Labs (formerly Regen Peptides) reviews and all 38 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.525% | How much of what's in the vial is the target compound |
| Amount in the vial | 26.66 mglabel says 20 mg · 33% more | Whether you get the amount on the label |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 20 mg · Lab measured 26.66 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 33% more means in a syringe
133% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 6.7 mg using the measured mass, against 5 mg on the label — 33% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | THYMU20-1121 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Midshire Labs (formerly Regen Peptides)'s Trust Score until Dec 2, 2027. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Sample label | Regen Peptides |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Jun 9, 2026 |
Independent HPLC purity analysis of Thymulin from Midshire Labs (formerly Regen Peptides), performed by Janoshik Labs on December 2, 2025. Reported purity: 99.525%. Net content: 26.66 mg against 20 mg labeled (133% of label). Tested content exceeds the labeled amount by 33%. Batch THYMU20-1121. Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 46 other Thymalin tests on Peptigrity have a typical purity of 99.77%. This one is 99.525%.