Thymosin-Alpha 1 (A1) lab test from Modern Aminos, March 2026
Kovera Labs tested Thymosin-Alpha 1 (A1) from Modern Aminos on Mar 8, 2026. It measured 99.0225% purity and 11.51 mg against 10 mg on the label.
- In the vial
- 11.51 mgThe label says 10 mg, so 15% more.
- Tested by
- Kovera Labs
- Tested on
- Lot
- BX-P-H908
Not checked on Kovera Labs' portal
This certificate carries no lookup code. Kovera Labs has a public portal, so a report with a code can be looked up there.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 251 Thymosin-Alpha 1 (A1) lab tests →Thymosin-Alpha 1 (A1) pricesModern Aminos reviews and all 56 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.0225% | How much of what's in the vial is the target compound |
| Amount in the vial | 11.51 mglabel says 10 mg · 15% more | Whether you get the amount on the label |
| Container | Lyophilized powder | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 10 mg · Lab measured 11.51 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 15% more means in a syringe
115% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.9 mg using the measured mass, against 2.5 mg on the label — 15% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | BX-P-H908 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validKovera Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Modern Aminos' Trust Score until Mar 8, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Apr 13, 2026 |
Independent HPLC purity analysis of Thymosin alpha-1 from Modern Aminos, performed by Kovera Labs on March 8, 2026. Reported purity: 99.0225%. Net content: 11.51 mg against 10 mg labeled (115% of label). Tested content exceeds the labeled amount by 15%. Batch BX-P-H908. Sample source: shop-provided. Certificate of analysis attached.
Other lots of Thymosin-Alpha 1 (A1) from Modern Aminos
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| HX-P-H794 | Jan 21, 2026 | Freedom Diagnostics | 99.45% | 109% of label | Not checked |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 250 other Thymosin-Alpha 1 (A1) tests on Peptigrity have a typical purity of 99.60%. This one is 99.0225%.