Forumlongevatech.com - investigation · Shop talk · 4 replies

Thymosin-Alpha 1 (A1) 10mg lab test from Peptira, August 2025

Janoshik Labs tested Thymosin-Alpha 1 (A1) 10mg from Peptira on Aug 29, 2025. It measured 99.326% purity and 10.78 mg against 10 mg on the label.

HPLC purity
99.326%
✓ Excellent
Excellent means 98% or higher.
In the vial
10.78 mgThe label says 10 mg, so 8% more.
Tested by
Janoshik Labs
Tested on
Lot
TA1-10-001
See the certificate ↓

Not checked on Janoshik Labs' portal

This certificate carries no lookup code. Janoshik Labs has a public portal, so a report with a code can be looked up there.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.326%How much of what's in the vial is the target compound
Amount in the vial10.78 mglabel says 10 mg · 8% moreWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 10 mg · Lab measured 10.78 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 8% more means in a syringe

108% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.7 mg using the measured mass, against 2.5 mg on the label — 8% more.

Certificate of analysis

Original document
Issued by Janoshik Labs · Aug 29, 2025 · Batch TA1-10-001

About this test

How this certificate was checked

Report numberTA1-10-001
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Peptira's Trust Score until Aug 29, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Apr 9, 2026
Summary

Independent HPLC purity analysis of Thymosin Alpha-1 10mg from Peptira, performed by Janoshik Labs on August 29, 2025. Reported purity: 99.326%. Net content: 10.78 mg against 10 mg labeled (108% of label). Batch TA1-10-001. Sample source: shop-provided. Certificate of analysis attached.

Other lots of Thymosin-Alpha 1 (A1) from Peptira

LotTestedLabPurityvs labelLab's portal
TA1-5-002Jan 11, 2026Freedom Diagnostics99.64%90% of labelNot checked
TBS-10-004Dec 18, 2025Freedom Diagnostics99.295%105% of labelNot checked
TA1-5-0601Dec 15, 2025Freedom Diagnostics99.915%126% of labelNot checked
TBS-10-003Nov 20, 2025Freedom Diagnostics99.444%119% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.