Forumlongevatech.com - investigation · Shop talk · 4 replies

SS-31 (Elamipretide) lab test from Felix Chemical Supply, December 2025

Freedom Diagnostics tested SS-31 (Elamipretide) from Felix Chemical Supply on Dec 23, 2025. It measured 99.837% purity and 28.54 mg against 25 mg on the label.

HPLC purity
99.837%
✓ Excellent
Excellent means 98% or higher.
In the vial
28.54 mgThe label says 25 mg, so 14% more.
Tested on
Lot
121925-SS-C
See the certificate ↓

Not checked on Freedom Diagnostics' portal

This certificate carries no lookup code. Freedom Diagnostics has a public portal, so a report with a code can be looked up there.

Freedom Diagnostics' site says: “Enter that code below and click Look up . The Search Code is always the first 4 characters of your company name followed by your accession number.”

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.837%How much of what's in the vial is the target compound
Amount in the vial28.54 mglabel says 25 mg · 14% moreWhether you get the amount on the label
ContainerWhite Lyophilized Powder
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 25 mg · Lab measured 28.54 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 14% more means in a syringe

114% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 7.1 mg using the measured mass, against 6.3 mg on the label — 14% more.

Certificate of analysis

Original document
Issued by Freedom Diagnostics · Dec 23, 2025 · Batch 121925-SS-C

About this test

How this certificate was checked

Report number121925-SS-C
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Felix Chemical Supply's Trust Score until Dec 23, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed May 3, 2026
Summary

Independent HPLC purity analysis of SS-31 from Felix Chemical Supply, performed by Freedom Diagnostics on December 23, 2025. Reported purity: 99.837%. Net content: 28.54 mg against 25 mg labeled (114% of label). Tested content exceeds the labeled amount by 14%. Batch 121925-SS-C. Sample source: shop-provided. Certificate of analysis attached.

Other lots of SS-31 (Elamipretide) from Felix Chemical Supply

LotTestedLabPurityvs labelLab's portal
010726-SS6-0Jan 12, 2026Freedom Diagnostics99.938%117% of labelNot checked
111325-SS6-6Nov 18, 2025Freedom Diagnostics99.658%96% of labelNot checked
102525-SS6-3Oct 31, 2025Freedom Diagnostics99.929%97% of labelNot checked
090825-SS2-DSep 9, 2025Chromate99.913%98% of labelNot checked
071025-SS6-5Jul 19, 2025Chromate99.804%99% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.