Forumlongevatech.com - investigation · Shop talk · 4 replies

SNAP-8 1000mg lab test from Glacier Aminos, lot SNPRGA-01, May 2026

ILS Laboratories tested SNAP-8 1000mg from Glacier Aminos on May 18, 2026. It measured 99.71% purity and 1000 mg against 1000 mg on the label.

HPLC purity
99.71%
✓ Excellent
Excellent means 98% or higher.
In the vial
1000 mgThe label says 1000 mg.
Tested on
Lot
SNPRGA-01
See the certificate ↓

Not checked on ILS Laboratories' portal

This certificate carries no lookup code. ILS Laboratories has a public portal, so a report with a code can be looked up there.

ILS Laboratories' site says: “Every COA we issue includes a unique QR code. Anyone — your customers, regulators, or distribution partners — can scan it to instantly verify the authenticity of the results.”

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.71%How much of what's in the vial is the target compound
Amount in the vial1000 mglabel says 1000 mgWhether you get the amount on the label
ContainerRaw Material
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 1000 mg · Lab measured 1000 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What this means in a syringe

100% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 250 mg on both the label figure and the measured one.

Certificate of analysis

Original document
Issued by ILS Laboratories · May 18, 2026 · Batch SNPRGA-01

About this test

How this certificate was checked

Report numberSNPRGA-01
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validILS Laboratories' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Glacier Aminos' Trust Score until May 18, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed May 19, 2026
Summary

Independent HPLC purity analysis of SNAP-8 RAW from Glacier Aminos, performed by ILS Laboratories on May 18, 2026. Reported purity: 99.71%. Net content: 1000 mg against 1000 mg labeled (100% of label). Batch SNPRGA-01. Sample source: shop-provided. Certificate of analysis attached.

Other lots of SNAP-8 from Glacier Aminos

LotTestedLabPurityvs labelLab's portal
AHIB04-01May 11, 2026—99.89%100% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.