Semax 10mg lab test from TriVial BioWorks, February 2026
Chromate tested Semax 10mg from TriVial BioWorks on Feb 17, 2026. It measured 99.37% purity and 11.22 mg against 10 mg on the label.
- In the vial
- 11.22 mgThe label says 10 mg, so 12% more.
- Tested by
- Chromate
- Tested on
- Lot
- SX10-0213
Confirmed on Chromate's portal · checked Feb 17, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
TRIVIALBK982Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 335 Semax lab tests →Semax pricesTriVial BioWorks reviews and all 66 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.37% | How much of what's in the vial is the target compound |
| Amount in the vial | 11.22 mglabel says 10 mg · 12% more | Whether you get the amount on the label |
| Endotoxin | < 0.0446 EU/mg | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | <50 ppb | Could there be metal contamination? |
| Container | Lyophilized Peptide Vial | |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.
What’s in the vial
Label 10 mg · Lab measured 11.22 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 12% more means in a syringe
112% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.8 mg using the measured mass, against 2.5 mg on the label — 12% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 32871 |
|---|---|
| On the lab's portal | ✓ Confirmed Aug 24, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| What the portal shows | That the report is validChromate's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward TriVial BioWorks' Trust Score until Feb 17, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Aug 24, 2026 |
Independent HPLC purity analysis of SEMAX from TriVial BioWorks, performed by Chromate on February 17, 2026. Reported purity: 99.37%. Net content: 11.22 mg against 10 mg labeled (112% of label). Tested content exceeds the labeled amount by 12%. Endotoxins: <0.0446 EU/mg. Heavy metals: <50 ppb. Batch SX10-0213. Sample source: shop-provided. Certificate of analysis attached.
Other lots of Semax from TriVial BioWorks
Related lab tests
The 332 other Semax tests on Peptigrity have a typical purity of 99.52%. This one is 99.37%.

Community discussion