Semax 11mg lab test from PrymaLab, January 2026
Janoshik Labs tested Semax 11mg from PrymaLab on Jan 7, 2026. It measured 99.39% purity and 12.09 mg against 11 mg on the label.
- In the vial
- 12.09 mgThe label says 11 mg, so 10% more.
- Tested by
- Janoshik Labs
- Tested on
- Lot
- 001
Confirmed on Janoshik Labs' portal · checked Jan 7, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
9BBK77EJGE4SSample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 335 Semax lab tests →Semax pricesPrymaLab reviews
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.39% | How much of what's in the vial is the target compound |
| Amount in the vial | 12.09 mglabel says 11 mg · 10% more | Whether you get the amount on the label |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 11 mg · Lab measured 12.09 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 10% more means in a syringe
110% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 3 mg using the measured mass, against 2.8 mg on the label — 10% more.
Certificate of analysis




About this test
How this certificate was checked
| Report number | 96920 |
|---|---|
| On the lab's portal | ✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal. |
| What the portal shows | That the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward PrymaLab's Trust Score until Jan 7, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | @BigMikePryma ● Member |
Independent HPLC purity analysis of SEMAX from PrymaLab, performed by Janoshik Labs on January 7, 2026. Reported purity: 99.39%. Net content: 12.09 mg against 11 mg labeled (110% of label). Batch 001. Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 332 other Semax tests on Peptigrity have a typical purity of 99.52%. This one is 99.39%.
Community discussion