Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

Semax 30mg lab test from Peptide Partners, September 2026

Chromate tested Semax 30mg from Peptide Partners on Sep 2, 2026. It measured 99.418% purity and 27.66 mg against 30 mg on the label.

HPLC purity
99.418%
✓ Excellent
Excellent means 98% or higher.
In the vial
27.66 mgThe label says 30 mg, so 8% less.
Tested by
Chromate
Tested on
Lot
SX2622
See the certificate ↓

Confirmed on Chromate's portal · checked Sep 2, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeGLZ3KE38HYS6

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.418%How much of what's in the vial is the target compound
Amount in the vial27.66 mglabel says 30 mg · 8% lessWhether you get the amount on the label
Endotoxin< 2.5 EU/vialIs it safe to inject? Checks for bacterial toxins
Heavy metals< 50 ppbCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 30 mg · Lab measured 27.66 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 8% less means in a syringe

92% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 6.9 mg using the measured mass, against 7.5 mg on the label — 8% less.

Certificate of analysis

Original document
Issued by Chromate · Sep 2, 2026 · Batch SX2622

About this test

How this certificate was checked

Report number39035
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validChromate's portal doesn't show the numbers, so they can't be compared there.
Submitted viaPeptigrity staff
Counts asOne lab testCounts toward Peptide Partners' Trust Score until Sep 2, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted by@Peptigrity 👑 Legend
Summary

Independent HPLC purity analysis of SEMAX from Peptide Partners, performed by Chromate on September 2, 2026. Reported purity: 99.418%. Net content: 27.66 mg against 30 mg labeled (92% of label). Endotoxins: < 2.5 EU/vial. Heavy metals: < 50 ppb. Batch SX2622. Sample source: shop-provided. Certificate of analysis attached.

Other lots of Semax from Peptide Partners

LotTestedLabPurityvs labelLab's portal
SX202603Mar 31, 2026Kovera Labs99.921%99% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

6 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.