Forumlongevatech.com - investigation · Shop talk · 4 replies

PT-141 50mg lab test from Precisely Peptides, April 2026

Vanguard Laboratory tested PT-141 50mg from Precisely Peptides on Apr 23, 2026. It measured 99.8% purity and 55.15 mg against 50 mg on the label.

HPLC purity
99.8%
✓ Excellent
Excellent means 98% or higher.
In the vial
55.15 mgThe label says 50 mg, so 10% more.
Tested on
Lot
PP412-26-001
See the certificate ↓

Not checked on Vanguard Laboratory's portal

This certificate carries no lookup code. Vanguard Laboratory has a public portal, so a report with a code can be looked up there.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.8%How much of what's in the vial is the target compound
Amount in the vial55.15 mglabel says 50 mg · 10% moreWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 50 mg · Lab measured 55.15 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 10% more means in a syringe

110% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 13.8 mg using the measured mass, against 12.5 mg on the label — 10% more.

Certificate of analysis

Original document
Issued by Vanguard Laboratory · Apr 23, 2026 · Batch PP412-26-001

About this test

How this certificate was checked

Report numberPP412-26-001
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validVanguard Laboratory's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Precisely Peptides' Trust Score until Apr 23, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Jun 13, 2026
Summary

Independent HPLC purity analysis of PT-141 from Precisely Peptides, performed by Vanguard Laboratory on April 23, 2026. Reported purity: 99.8%. Net content: 55.15 mg against 50 mg labeled (110% of label). Tested content exceeds the labeled amount by 10%. Batch PP412-26-001. Sample source: shop-provided. Certificate of analysis attached.

Other lots of PT-141 from Precisely Peptides

LotTestedLabPurityvs labelLab's portal
PP412-26-001Apr 24, 2026Vanguard Laboratory99.35%125% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.