PT-141 10mg lab test from Felix Chemical Supply, March 2025
Chromate tested PT-141 10mg from Felix Chemical Supply on Mar 5, 2025. It measured 99.682% purity and 10.95 mg against 10 mg on the label.
- In the vial
- 10.95 mgThe label says 10 mg, so 10% more.
- Tested by
- Chromate
- Tested on
- Lot
- 022825-PT10
Not checked on Chromate's portal
This certificate carries no lookup code. Chromate has a public portal, so a report with a code can be looked up there.
Chromate's site says: “Click 'Verify' (top right), then enter Job Number + Access Code from the COA”
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 290 PT-141 lab tests →PT-141 pricesFelix Chemical Supply reviews and all 280 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.682% | How much of what's in the vial is the target compound |
| Amount in the vial | 10.95 mglabel says 10 mg · 10% more | Whether you get the amount on the label |
| Container | Lyophilized peptide vial | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 10 mg · Lab measured 10.95 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 10% more means in a syringe
110% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.7 mg using the measured mass, against 2.5 mg on the label — 10% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 022825-PT10 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validChromate's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Felix Chemical Supply's Trust Score until Mar 5, 2027. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed May 3, 2026 |
Independent HPLC purity analysis of PT-141 from Felix Chemical Supply, performed by Chromate on March 5, 2025. Reported purity: 99.682%. Net content: 10.95 mg against 10 mg labeled (110% of label). Batch 022825-PT10. Sample source: shop-provided. Certificate of analysis attached.
Other lots of PT-141 from Felix Chemical Supply
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| 020526-PTS-0 | Feb 12, 2026 | Freedom Diagnostics | 99.845% | 178% of label | Not checked |
| 120425-PT-8 | Dec 8, 2025 | Freedom Diagnostics | 99.838% | 111% of label | Not checked |
| 092525-PT-1 | Oct 1, 2025 | Freedom Diagnostics | 99.198% | 94% of label | Not checked |
| 091025-PT1-1 | Sep 11, 2025 | Chromate | 99.938% | 107% of label | Not checked |
| 090225-PT10-A | Sep 8, 2025 | Chromate | 99.932% | 99% of label | Not checked |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 287 other PT-141 tests on Peptigrity have a typical purity of 99.82%. This one is 99.682%.

Community discussion