Forumlongevatech.com - investigation · Shop talk · 4 replies

NAD+ 1000mg lab test from River City Aminos, May 2026

Vanguard Laboratory tested NAD+ 1000mg from River City Aminos on May 6, 2026. It measured 99.1% purity and 1034 mg against 1000 mg on the label.

HPLC purity
99.1%
✓ Excellent
Excellent means 98% or higher.
In the vial
1034 mgThe label says 1000 mg, so 3% more.
Tested on
Lot
RCA-NAD1K4.26-1001
See the certificate ↓

Not checked on Vanguard Laboratory's portal

This certificate carries no lookup code. Vanguard Laboratory has a public portal, so a report with a code can be looked up there.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.1%How much of what's in the vial is the target compound
Amount in the vial1034 mglabel says 1000 mg · 3% moreWhether you get the amount on the label
ContainerTwo amber vials
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 1000 mg · Lab measured 1034 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 3% more means in a syringe

103% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 258.5 mg using the measured mass, against 250 mg on the label — 3% more.

Certificate of analysis

Original document
Issued by Vanguard Laboratory · May 6, 2026 · Batch RCA-NAD1K4.26-1001

About this test

How this certificate was checked

Report numberV260427-14 002
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validVanguard Laboratory's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward River City Aminos' Trust Score until May 6, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Aug 26, 2026
Summary

Independent HPLC purity analysis of NAD+ from River City Aminos, performed by Vanguard Laboratory on May 6, 2026. Reported purity: 99.1%. Net content: 1034 mg against 1000 mg labeled (103% of label). Batch RCA-NAD1K4.26-1001. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

7 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.