Forumlongevatech.com - investigation · Shop talk · 4 replies

NAD+ 1000mg lab test from NorthStar Compounds, September 2026

Axiom Analytics tested NAD+ 1000mg from NorthStar Compounds on Sep 19, 2026. It measured 99.97% purity and 1064.81 mg against 1000 mg on the label.

HPLC purity
99.97%
✓ Excellent
Excellent means 98% or higher.
In the vial
1064.81 mgThe label says 1000 mg, so 6% more.
Tested on
Lot
N12604
See the certificate ↓

Confirmed on Axiom Analytics' portal · checked Sep 19, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeD659-B876-86BE

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.97%How much of what's in the vial is the target compound
Amount in the vial1064.81 mglabel says 1000 mg · 6% moreWhether you get the amount on the label
Endotoxin0.068 EU/mg · passIs it safe to inject? Checks for bacterial toxins
ContainerClear Cap / Aluminum Crimp
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 1000 mg · Lab measured 1064.81 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 6% more means in a syringe

106% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 266.2 mg using the measured mass, against 250 mg on the label — 6% more.

Certificate of analysis

Original document
Issued by Axiom Analytics · Sep 19, 2026 · Batch N12604

About this test

How this certificate was checked

Report numberAX-2026-1278-D83W
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validAxiom Analytics' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward NorthStar Compounds' Trust Score until Sep 19, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 01 · Peptigrity team · filed Sep 22, 2026
Summary

Independent HPLC purity analysis of NAD+ from NorthStar Compounds, performed by Axiom Analytics on September 19, 2026. Reported purity: 99.97%. Net content: 1064.81 mg against 1000 mg labeled (106% of label). Endotoxins: 0.068 EU/mg - PASS. Batch N12604. Sample source: shop-provided. Certificate of analysis attached.

Other lots of NAD+ from NorthStar Compounds

LotTestedLabPurityvs labelLab's portal
N52603Sep 1, 2026Kovera Labs99.483%103% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

6 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.