Forumlongevatech.com - investigation · Shop talk · 4 replies

NAD+ 500mg lab test from Double R Labs, June 2026

Kovera Labs tested NAD+ 500mg from Double R Labs on Jun 20, 2026. It measured 99.676% purity and 537.47 mg against 500 mg on the label.

HPLC purity
99.676%
✓ Excellent
Excellent means 98% or higher.
In the vial
537.47 mgThe label says 500 mg, so 7% more.
Tested by
Kovera Labs
Tested on
Lot
DRL-06-NJ50
See the certificate ↓

Confirmed on Kovera Labs' portal · checked Jun 20, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeT2WBQJO

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.676%How much of what's in the vial is the target compound
Amount in the vial537.47 mglabel says 500 mg · 7% moreWhether you get the amount on the label
Endotoxin< 0.5 EU/mLIs it safe to inject? Checks for bacterial toxins
Heavy metalsArsenic, Cadmium, Lead, Mercury all NegativeCould there be metal contamination?
ContainerBlack Cap / Silver Crimp
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 500 mg · Lab measured 537.47 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 7% more means in a syringe

107% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 134.4 mg using the measured mass, against 125 mg on the label — 7% more.

Certificate of analysis

Original document
Issued by Kovera Labs · Jun 20, 2026 · Batch DRL-06-NJ50

About this test

How this certificate was checked

Report numberKVR-2026-9CFEF4
On the lab's portal✓ Confirmed Jul 28, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
What the portal showsThat the report is validKovera Labs' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Double R Labs' Trust Score until Jun 20, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Jul 28, 2026
Summary

Independent HPLC purity analysis of NAD+ from Double R Labs, performed by Kovera Labs on June 20, 2026. Reported purity: 99.676%. Net content: 537.47 mg against 500 mg labeled (107% of label). Endotoxins: <0.5 EU/mL. Heavy metals: Arsenic, Cadmium, Lead, Mercury all Negative. Batch DRL-06-NJ50. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.