HomeLab Tests hightidecompounds peptides, MOTS-C
Purity · pass✓ Lab-verifiedShop-provided sample

MOTS-C × hightidecompounds peptides — lab test, lot MS10-005, August 2026

Lotlook this batch up across every shop →Check another lot
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
99.855%
Excellent purity only
↓ Download COA
Independently confirmed on the lab’s portal✓ Extra check

COA KVR-2026-A42783 matches Kovera Labs's public record. So this test doesn't rest on our review alone — the lab confirms it too.

Lookup codeCH56N96
Look it up on Kovera Labs ↗Checked Aug 19, 2026

Test results

9 data points
Purity
99.855%
Endotoxins
<0.5 EU/mL PASS
Heavy metals
As, Cd, Pb, Hg — all Negative
Stated qty
10 mg
Tested qty
9.19 mg
Qty match
92% of labeled · -8%
Batch / Lot
MS10-005
COA number
KVR-2026-A42783
Container
Lyophilized Powder / Black Cap / Silver Crimp
Tested by
Kovera LabsView profile →

About this test

What’s in the vial

Label 10 mg · Lab measured 9.19 mg

92% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.3 mg using the measured mass, against 2.5 mg on the label — 8% less.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report numberKVR-2026-A42783
Portal lookup✓ Lab-verified
Checked25 Aug 2026date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
PDF vs portalKovera Labs's portal shows validity only
WeightCounts as one lab test

Independent HPLC purity analysis of MOTS-C from hightidecompounds peptides, performed by Kovera Labs on August 19, 2026. Reported purity: 99.855%. Net content: 9.19 mg against 10 mg labeled (92% of label). Endotoxins: <0.5 EU/mL PASS. Heavy metals: As, Cd, Pb, Hg — all Negative. Batch MS10-005. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by Kovera Labs · Aug 19, 2026 · Batch MS10-005

Other lots of MOTS-C from hightidecompounds peptides

LotTestedLabPurityvs labelStatus
MS10-00419 Aug 2026Kovera Labs99.704%99%✓ Lab-verified
MS40-0016 Aug 2026Kovera Labs99.555%107%✓ Lab-verified
MS10-00315 Jul 2026Kovera Labs99.558%102%✓ Lab-verified
MS10-00220 Jun 2026Kovera Labs99.391%106%✓ Lab-verified
MOT10-00126 May 2026Kovera Labs98.833%96%✓ Lab-verified

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

The 569 other MOTS-C tests on Peptigrity range from 95.49% to 99.99%. This one sits at 99.86%.

More from hightidecompounds peptides
More MOTS-C tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.