MK-677 25mg lab test from Chemyo, December 2025
Nutri Analytical tested MK-677 25mg from Chemyo on Dec 1, 2025. It measured 99.37% purity and 25.36 mg against 25 mg on the label.
- In the vial
- 25.36 mgThe label says 25 mg, so 1% more.
- Tested by
- Nutri Analytical
- Tested on
- Lot
- BA2183-2
Nutri Analytical has no public portal.
Only the lab can confirm this report, by email.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
Chemyo reviews and all 17 lab testsClosed
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.37% | How much of what's in the vial is the target compound |
| Amount in the vial | 25.36 mglabel says 25 mg · 1% more | Whether you get the amount on the label |
| Container | Solution 25mg/ml - 50ml | |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 25 mg · Lab measured 25.36 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 1% more means in a syringe
101% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 6.3 mg using the measured mass, against 6.3 mg on the label — 1% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | BA2183-2 |
|---|---|
| On the lab's portal | Lab has no portalThis laboratory publishes no public lookup, so the report cannot be confirmed independently. |
| What the portal shows | That the report is validNutri Analytical's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Chemyo's Trust Score until Dec 1, 2027. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Apr 17, 2026 |
Independent HPLC purity analysis of MK-677 from Chemyo, performed by Nutri Analytical on December 1, 2025. Reported purity: 99.37%. Net content: 25.36 mg against 25 mg labeled (101% of label). Batch BA2183-2. Sample source: shop-provided. Certificate of analysis attached.

Community discussion