COA KVR-2026-A379CE matches Kovera Labs's public record. So this test doesn't rest on our review alone — the lab confirms it too.
JKJFI4ILabel 5 mg · Lab measured 5.34 mg
107% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.3 mg using the measured mass, against 1.3 mg on the label — 7% more.
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
| Report number | KVR-2026-A379CE |
|---|---|
| Portal lookup | ✓ Lab-verified |
| Checked | 24 Aug 2026date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| PDF vs portal | Kovera Labs's portal shows validity only |
| Weight | Counts as one lab test |
Independent HPLC purity analysis of LL-37 from trivialbioworks peptides, performed by Kovera Labs on April 5, 2026. Reported purity: 99.939%. Net content: 5.34 mg against 5 mg labeled (107% of label). Endotoxins: PASS (≤0.5 EU/mL). Heavy metals: Arsenic, Cadmium, Lead, Mercury — all Negative. Batch L37-0331. Sample source: shop-provided. Certificate of analysis attached.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.
Community discussion