HomeLab Tests Peptide Plugs, LL-37
Purity · pass✓ Lab-verifiedShop-provided sample

LL-37 × Peptide Plugs — lab test, July 2026

Lotlook this batch up across every shop →Check another lot
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
99.65%
Excellent purity only
↓ Download COA
Independently confirmed on the lab’s portal✓ Extra check

COA 2607240085 matches freedomdiagnosticstesting.com's public record. So this test doesn't rest on our review alone — the lab confirms it too.

Lookup codePept2607240085

Test results

9 data points
Purity
99.65%
Endotoxins
Pass (<0.05 EU/mL)
Heavy metals
ICP-MS: Arsenic, Cadmium, Lead, and Mercury below reporting/specification limits; No Fentanyl Detected
Stated qty
5 mg
Tested qty
5.57 mg
Qty match
111% of labeled · +11%
Batch / Lot
175-01-DK
COA number
2607240085
Container
White Lyophilized Powder
Tested by

About this test

What’s in the vial

Label 5 mg · Lab measured 5.57 mg

111% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.4 mg using the measured mass, against 1.3 mg on the label — 11% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report number2607240085
Portal lookup✓ Lab-verified
Checked27 Aug 2026date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
PDF vs portalfreedomdiagnosticstesting.com's portal shows validity only
WeightCounts as one lab test

Independent HPLC purity analysis of LL-37 from Peptide Plugs, performed by freedomdiagnosticstesting.com on July 26, 2026. Reported purity: 99.65%. Net content: 5.57 mg against 5 mg labeled (111% of label). Tested content exceeds the labeled amount by 11%. Endotoxins: Pass (<0.05 EU/mL). Heavy metals: ICP-MS: Arsenic, Cadmium, Lead, and Mercury below reporting/specification limits; No Fentanyl Detected. Batch 175-01-DK. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by freedomdiagnosticstesting.com · Jul 26, 2026 · Batch 175-01-DK

Related lab tests

8 tests

The 63 other LL-37 tests on Peptigrity range from 91.08% to 99.98%. This one sits at 99.65%.

More from Peptide Plugs
More LL-37 tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.