L-Carnitine, Methionine, Inositol, Choline, B12, B6, NADH Blend lab test from Mindful Research, March 2026
MDx BioAnalytical Laboratory tested L-Carnitine, Methionine, Inositol, Choline, B12, B6, NADH Blend from Mindful Research on Mar 8, 2026. It measured 99.74% purity and 304.22 mg against 300 mg on the label.
- Amount measured
- 304.22 mgThe label says 300 mg, so 1% more.
- Tested by
- MDx BioAnalytical Laboratory
- Tested on
- Lot
- LCL0224
Not checked on MDx BioAnalytical Laboratory's portal
This certificate carries no lookup code. MDx BioAnalytical Laboratory has a public portal, so a report with a code can be looked up there.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.74% | How much of what's in the vial is the target compound |
| Amount measured | 304.22 mglabel says 300 mg · 1% more | Whether you get the amount on the label |
| Endotoxin | < 50.05 EU/mL | Is it safe to inject? Checks for bacterial toxins |
| Container | Amber/orange glass bottle with label | |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 300 mg · Lab measured 304.22 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
Certificate of analysis
About this test
How this certificate was checked
| Report number | LCL0224 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validMDx BioAnalytical Laboratory's portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab test |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Mar 25, 2026 |
Independent HPLC purity analysis of L-Carnitine, Methionine, Inositol, Choline, B12, B6, NADH Blend from Mindful Research, performed by MDx BioAnalytical Laboratory on March 8, 2026. Reported purity: 99.74%. Net content: 304.22 mg against 300 mg labeled (101% of label). Endotoxins: <50.05 EU/mL. Batch LCL0224. Sample source: shop-provided. Certificate of analysis attached.

Community discussion