Forumlongevatech.com - investigation · Shop talk · 4 replies

KPV 10mg lab test from Perfect Peptides, May 2026

Chromate tested KPV 10mg from Perfect Peptides on May 31, 2026. It measured 99.473% purity and 9.63 mg against 10 mg on the label.

HPLC purity
99.473%
✓ Excellent
Excellent means 98% or higher.
In the vial
9.63 mgThe label says 10 mg, so 4% less.
Tested by
Chromate
Tested on
Lot
PP030426
See the certificate ↓

Confirmed on Chromate's portal · checked May 31, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codePERFECT72856

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.473%How much of what's in the vial is the target compound
Amount in the vial9.63 mglabel says 10 mg · 4% lessWhether you get the amount on the label
Endotoxin< 1 EU/vialIs it safe to inject? Checks for bacterial toxins
Heavy metals< 50 ppbCould there be metal contamination?
ContainerLyophilized peptide vial with blue cap
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 10 mg · Lab measured 9.63 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 4% less means in a syringe

96% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.4 mg using the measured mass, against 2.5 mg on the label — 4% less.

Certificate of analysis

Original document
Issued by Chromate · May 31, 2026 · Batch PP030426

About this test

How this certificate was checked

Report number#35639
On the lab's portal✓ Confirmed Jul 18, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
What the portal showsThat the report is validChromate's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Perfect Peptides' Trust Score until May 31, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Jul 18, 2026
Summary

Independent HPLC purity analysis of KPV from Perfect Peptides, performed by Chromate on May 31, 2026. Reported purity: 99.473%. Net content: 9.63 mg against 10 mg labeled (96% of label). Endotoxins: < 1 EU/vial. Heavy metals: < 50 ppb. Batch PP030426. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

6 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.