Forumlongevatech.com - investigation · Shop talk · 4 replies

Ipamorelin 10mg supplier's lab test, sold by Peptuvia, September 2026

Freedom Diagnostics tested Ipamorelin 10mg from Peptuvia on Sep 2, 2026. It measured 99.61% purity and 8.17 mg against 10 mg on the label.

HPLC purity
99.61%
✓ Excellent
Excellent means 98% or higher.
In the vial
8.17 mgThe label says 10 mg, so 18% less.
Tested on
Lot
2026083310
See the certificate ↓

Confirmed on Freedom Diagnostics' portal · checked Sep 2, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

The portal confirms the certificate. It can't show that a vial you buy from Peptuvia is from this batch — compare the lot on yours.

Lookup codeG2608310652

Sample source: supplier-provided. Peptuvia's supplier had this batch tested before it reached Peptuvia, and Peptuvia passed the certificate on. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.61%How much of what's in the vial is the target compound
Amount in the vial8.17 mglabel says 10 mg · 18% lessWhether you get the amount on the label
Endotoxin≤ 0.05 EU/mL · passIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 10 mg · Lab measured 8.17 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 18% less means in a syringe

82% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2 mg using the measured mass, against 2.5 mg on the label — 18% less.

Certificate of analysis

Original document
Issued by Freedom Diagnostics · Sep 2, 2026 · Batch 2026083310

About this test

How this certificate was checked

Report number2608310652
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there.
Counts asListed for information — supplier-provided, not counted
Sample sourceSupplier-providedNo vial bought from Peptuvia was tested. If the lot on your vial reads 2026083310, this is your batch's certificate. Supplier certificates are listed for information and don't count toward the Trust Score.
Sample labelGenesys
Submitted by@Peptuvia 🏆 Elite
Summary

HPLC purity analysis of Ipamorelin 10mg sold by Peptuvia, ordered by its supplier and performed by Freedom Diagnostics on September 2, 2026. Reported purity: 99.61%. Net content: 8.17 mg against 10 mg labeled (82% of label). Tested content is 18% below the labeled amount. Endotoxins: Pass (2 replicates, LAL USP <85>, sensitivity ≤0.05 EU/mL). Batch 2026083310. Sample source: supplier-provided. Certificate of analysis attached.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?